Nova-tech PGL Series User Manual

Browse online or download User Manual for Scales Nova-tech PGL Series. Nova-Tech PGL Series User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - PGLSERIES

AdamEquipment PGLSERIES (P.N.9326,RevisionC5,March2009) 1 | Page © Adam Equipment Company 2008

Page 2

5.0 KEYPAD Thekeypadhasthefollowingkeystooperatethebalance.Keys Primaryfunction SecondaryfunctionToturnthebalancetoONorStandb

Page 3

5.1 NUMERICENTRYMETHOD Tosetavaluewhenrequired,usethekeysasgivenbelow‐ ‐[Up]and[Down]keystoincreaseordecreasetheflash

Page 4

6.0 BASICOPERATION 6.1 INITIALISATION1) Whenthebalanceisfirstswitchedon,itwilldisplaythebalanceserialnumber(ifset),softwarerevisi

Page 5

6.2 PASSCODESIf a passcode has beenset to limit access to the weighing functions of the balancethe display will show “PASSCODES”

Page 6 - 3.0 SETUP

6.4 WEIGHINGUNITSYoucanselectalternativeweighingunitstodisplaytheweightbypressingthe[Unit]key.Thecommonweighingunitsare:Unit

Page 7

7.0 FUNCTIONS When weighing, the user can access the applications that have been enabled (seesection12.2).• Weighing• Partscountin

Page 8

8) Duringpartscountingcheckswillbemadetodeterminethattheweightofthereference parts is large enough for reasonably accurate count

Page 9 - INDICATORS

12) Placeunknownsampletodisplaythepercentageweight13) To perform percent weighing with another sample press [Mode] andcontinuefrom

Page 10 - 5.0 KEYPAD

weighingunit.Ifthe weighingunitispounds: ounces the limit issetindecimalpounds,1.500lb=1lb8oz.4) Press[Enter]toproceed5)

Page 11

7.4DENSITYDETERMINATION Itispossibletodeterminethedensityofsolids orliquidsusingthis mode.Theuserselects the type of density t

Page 12 - 6.0 BASICOPERATION

EasyReference:Modelnameofthescale:Serialnumberoftheunit:Softwarerevisionnumber(Displayedwhenpowerisfirstturnedon):

Page 13

9) The balance will request the weight of the sample in air by displaying “AIR WEIGHT”. Place the item on the pan or receptacle,

Page 14

7) Thebalancewillrequesttheweightinairbydisplaying“AIR WEIGHT”.Placetheglassplumbsuppliedwiththedensitydeterminationkitinairon

Page 15 - 7.0 FUNCTIONS

8.0 CALIBRATIONThePGLseriescanonlybecalibratedwithanexternalmass.8.1 MANUALCALIBRATIONPressingthe[Cal] keywillstartcalibration.

Page 16

7) Placethemassonthebalance.Press[Enter]to continue8) On the PGL 203 and PGL 303 models the display will show the busy symbol

Page 17

8.4 CALIBRATIONREPORT Thecalibrationreportwillshowthedetailsfromthebalanceandgivetheuseraplacetosignshowinghedidthecalibratio

Page 18

9.0 RS‐232INTERFACE Thebalanceshavetheabilitytosendorreceivedataovertheserialinterface.The weighing data can be sent over the

Page 19 - DENSITYDETERMINATION

Ifoutputondemandisselected,theusermayoptionallyconfiguretheserialoutputas a choice of 3 styles of form, either in a default

Page 20

9.2 STANDARDFORMAT9.2 STANDARDFORMATThe balance will print the following data as the standard form. The standard formcannotbecha

Page 21

BasicInputCommands:!KT<CR>Taresthebalance todisplaythenetweight.Thisisthesameaspressingthe[Zero/Tare]keywhenthebalance

Page 22 - 8.0 CALIBRATION

10.0 BATTERYOPERATION Thescalemayoperatefromabuiltinleadacidbattery.Duringoperationwiththebatterythebacklightshould bedisabled

Page 23

CONTENTS2.0 INTRODUCTION ...5 3.0 SET UP...

Page 24

12.0 SUPERVISORMENUS Pressingthe[Setup]keywhileinnormalweighinggivesaccesstothemenus.1) When [Setup] is pressed and passcodes ar

Page 25 - 9.0 RS‐232INTERFACE

12.2 ENABLEWEIGHINGMODES Samestepsarefollowedtoenableordisabletheweighingmodes.1) Press[Enter]when“MODES”isdisplayed.Thedisplayw

Page 26

Formatofcustomforms#1and#2 IfFORM1orFORM2isselected,itcanbechangedbytheuserusingaselectionofavailabledata.Bydefaultthe2f

Page 27

Thenextlineshows:“LINENO2”“TIME”‐printstimeOnlyoneitemcanbeenteredperline.Continue until the formatting of the form is c

Page 28

1) Use the [Up] and [Down] keys to  increase or decrease the value for setting.Press[Enter]toacceptthesettingandadvancetothene

Page 29 - 11.0 ERRORCHECKING

12.6 PASSCODESTo enable the security features in this balance it is necessary to set passcodes.There are 2 passcodes called Opera

Page 30 - 12.0 SUPERVISORMENUS

13.0 SPECIFICATIONS  PGL203 PGL303 PGL2002 PGL3002MaximumCapacity 200 g 300g 2000g 3000gReadability 0.001g 0.001g 0.01g 0.

Page 31

 PGL10001 PGL20001MaximumCapacity 10kg 20kgReadability 0.1g 0.1gRepeatability(s.d.) 0.2g 0.2gLinearity± 0.4g 0.4gPan 400

Page 32

14.0 WARRANTYSTATEMENT Adam Equipment offers Limited Warranty (Parts and Labor) for the components failed due todefectsinmaterials

Page 33

Manufacturer’sDeclarationofConformityManufacturer’sDeclarationofConformityThisproducthasbeenmanufacturedinaccordance

Page 34

4 | Page © Adam Equipment Company 2008

Page 35

ADAM EQUIPMENTis anISO9001:2000 certifiedglobal companywith more than 35 yearsexperienceintheproductionandsaleofelectronicweigh

Page 36 - 13.0 SPECIFICATIONS

2.0 INTRODUCTION2.0 INTRODUCTIONThankyouforselectingthePGLBalance.ThankyouforselectingthePGLBalance.This Instruction Manual w

Page 37 - CommonSpecifications:

3.0 SETUP 3.1 UNPACKINGANDSETTINGUPYOURSCALERemove the balance from the packing by carefully lifting it out of the box.Inside

Page 38 - 14.0 WARRANTYSTATEMENT

3.3 LEVELLINGTHE BALANCE After placing the balance in a suitable place, level itbyusingthespiritlevelontherearofthebalance.

Page 39 - WEEE COMPLIANCE

3.5 LOCATINGANDPROTECTINGYOURSCALE In order to keep your scale functioning at its best we suggest that you do thefollowing:A

Page 40

4.0 DISPLAY TheLCDhasuniquesymbolstoindicate thefollowing: Î0Í ZeroStableNet Netweight A bar graph indicating the proportion of

Comments to this Manuals

No comments