8 | P a g e © Adam Equipment Company 2010 [Func/C] Selects the Functions of the scale. If the scale is weighing, it will select par

Page 3 - CONTENTS

9 | P a g e © Adam Equipment Company 2010 6.0 OPERATION 6.1 ZEROING THE DISPLAY • You can press the [Z/T] key at any time to set

Page 4 - 1.0 INTRODUCTION

10 | P a g e © Adam Equipment Company 2010 • Press the [Z/T] key to tare the scale. The weight that was displayed is stored as the t

Page 5 - 2.0 SPECIFICATIONS

11 | P a g e © Adam Equipment Company 2010 6.4 PARTS COUNTING If parts counting is enabled, See section 7.4, it is possib

Page 6 - 3.0 INSTALLATION

12 | P a g e © Adam Equipment Company 2010 • Press the [Pcs/] key to return to normal weighing. Press the [Pcs/] key again

Page 7

13 | P a g e © Adam Equipment Company 2010 BOTH LIMITS SET The display will show OK when the weight is between the limits F3

Page 8

14 | P a g e © Adam Equipment Company 2010 NOTE: Weight must be more than 20 scale divisions for check weighing to operate. Below 20

Page 9 - DESCRIPTIONS

15 | P a g e © Adam Equipment Company 2010 6.6 ACCUMULATED TOTAL • The scale can be set to accumulate manually by pressin

Page 10 - 5.0 DISPLAYS

16 | P a g e © Adam Equipment Company 2010 6.7 PERCENT WEIGHING The scale can be set to perform percent weighing. See Section 7.2

Page 11 - 6.0 OPERATION

17 | P a g e © Adam Equipment Company 2010 • The number of decimal points will depend on the weight used in comparison to the capacit

Page 12

© Adam Equipment Company 2010 Easy Reference: Model name of the scale: Serial number of the unit: Software re

Page 13

18 | P a g e © Adam Equipment Company 2010 6.8 ANIMAL (DYNAMIC) WEIGHING The scale can be set to animal (dynamic) weighing for weigh

Page 14

19 | P a g e © Adam Equipment Company 2010 6.8.1 ANIMAL WEIGHING PROCEDURE • With the platform empty the display will show zero weig

Page 15

20 | P a g e © Adam Equipment Company 2010 7.0 USER PARAMETERS Pressing the [Func/C] key during normal operation allows the

Page 16

21 | P a g e © Adam Equipment Company 2010 Parameter Description Options Default setting F1 Lo Set Low limit. Use the [Unit/

Page 17

22 | P a g e © Adam Equipment Company 2010 • Press [Print/M+/Esc] to return to the group “FUnC 2”. If you press [Print/M+

Page 18

23 | P a g e © Adam Equipment Company 2010 C3 PrM Printing Mode- Manual, Continuous or Automatic mAn, Cont (not on EC approved sca

Page 19

24 | P a g e © Adam Equipment Company 2010 This group of parameters is used to control the operation of the scale. Parameter Desc

Page 20

25 | P a g e © Adam Equipment Company 2010 8.0 BATTERY OPERATION • The scales can be operated from the battery if desired. The bat

Page 21

26 | P a g e © Adam Equipment Company 2010 3124 9.0 RS-232 INTERFACE The AE 402 indicator is supplied with bi-directional

Page 22 - PARAMETERS

27 | P a g e © Adam Equipment Company 2010 Data Format-Normal Output: Only weight value along with the weighing unit is prin

Page 23

1 | P a g e © Adam Equipment Company 2010 CONTENTS 1.0 INTRODUCTION...

Page 24 - Baud Rate

28 | P a g e © Adam Equipment Company 2010 Data Format- Memory Recall Output: Data Format- Continuous Output- Normal weighing: D

Page 25 - PRINT SETTINGS

29 | P a g e © Adam Equipment Company 2010 Description ENGLISH FRENCH GERMAN SPANISH Net weight Net Wt. Pds Net Net-Gew Pso

Page 26

30 | P a g e © Adam Equipment Company 2010 10.0 RELAY INTERFACE The AE 402 indicator is supplied with drivers to control external

Page 27 - OPERATION

31 | P a g e © Adam Equipment Company 2010 11.0 CALIBRATION The scale can be calibrated using the following procedure. To ente

Page 28 - INTERFACE

32 | P a g e © Adam Equipment Company 2010 12.0 SERVICE SECTION The scales will allow entry to the parameters if the [Tare] key

Page 29

33 | P a g e © Adam Equipment Company 2010 The parameters available are: “F4 Int” Initial Zero Range “F5 rEZ” Re-Zero

Page 30

34 | P a g e © Adam Equipment Company 2010 12.3 PARAMETER DETAILS 12.3.1 F1 -CALIBRATION To enter the calibration parameter, pr

Page 31

35 | P a g e © Adam Equipment Company 2010 12.3.3 F3 – CAPACITY/ WEIGHING UNIT/INCREMENT To enter this parameter, press the [Z/T]

Page 32 - 10.0 RELAY

36 | P a g e © Adam Equipment Company 2010 12.3.4 F4 –INITIAL ZERO RANGE To enter this parameter, press the [Z/T] key when “F4 int”

Page 33 - 11.0 CALIBRATION

37 | P a g e © Adam Equipment Company 2010 12.3.9 F9 –LOW VOLTAGE DETECTION This parameter allows detection of low voltage when t

Page 34 - SECTION

2 | P a g e © Adam Equipment Company 2010 1.0 INTRODUCTION • The AE 402 indicator provides the user with the electronics necessar

Page 35

38 | P a g e © Adam Equipment Company 2010 13.0 ERROR CODES ERROR CODES DESCRIPTION SUGGESTIONS - -oL - - Over-range Remove weig

Page 36

39 | P a g e © Adam Equipment Company 2010 14.0 REPLACEMENT PARTS AND ACCESSORIES If you need to order any spare parts and accesso

Page 37

40 | P a g e © Adam Equipment Company 2010 16.0 WARRANTY STATEMENT Adam Equipment offers Limited Warranty (Parts and Labour) for th

Page 38

© Adam Equipment Company 2010 Manufacturer’s Declaration of Conformity This product has been manufactured in accordance with the harm

Page 39

© Adam Equipment Company 2010 ADAM EQUIPMENT is an ISO 9001:2008 certified global company with more than 35 years experience in

Page 40 - 13.0 ERROR

3 | P a g e © Adam Equipment Company 2010 2.0 SPECIFICATIONS External resolution ratio 1/1000-1/30000 Non-linear error ±0.016% F

Page 41

4 | P a g e © Adam Equipment Company 2010 3.0 INSTALLATION 3.1 LOCATING THE SCALES • The scales should not be plac

Page 42 - STATEMENT

5 | P a g e © Adam Equipment Company 2010 3.3 SETTING UP THE SCALES • Attach the power supply module to the connector on the side

Page 43

6 | P a g e © Adam Equipment Company 2010 31243.4.2 CONNECTION OF RS-232 RS-232 serial interface is a plug as figure 2 shows:

Page 44

7 | P a g e © Adam Equipment Company 2010 4.0 KEY DESCRIPTIONS [>Z/T<] If near zero, Sets the zero point for all subse