Nova-tech CBK Series User Manual

Browse online or download User Manual for Scales Nova-tech CBK Series. Nova-Tech CBK Series User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - CBK SERIES

© Adam Equipment Company 2007 Adam Equipment CBK SERIES (P.N. 8509, Revision A7, August 2007) Software Rev.: 4.28 & above

Page 2

© Adam Equipment Company 2007 8 5.0 DISPLAY 6.0 SYMBOLS AND INDICATORS The LCD has unique symbols to indicate the following: 0 The di

Page 3 - CONTENTS

© Adam Equipment Company 2007 9 7.0 BATTERY • The scales can be operated from the battery, if desired. The battery life is approxima

Page 4 - 1.0 INTRODUCTION

© Adam Equipment Company 2007 10 10.0 OPERATIONS 10.1 ZEROING • You can press the [Zero] key at any time to set the zero point fr

Page 5 - 2.0 SPECIFICATIONS

© Adam Equipment Company 2007 11 NOTE: When the container is removed a negative value will be shown. If the scale was tared just before removing

Page 6 - 3.0 INSTALLATION

© Adam Equipment Company 2007 12 • If a container is to be used, place this container on the platform before entering parts counting a

Page 7 - 3.2 LOCATING

© Adam Equipment Company 2007 13 • To count a different sample quantity, pre

Page 8

© Adam Equipment Company 2007 14 3. If Limit Password is enabled then enter the password which will allow you to change the limits or the operat

Page 9 - 4.0 KEYPAD

© Adam Equipment Company 2007 15 10.6 LIMITS STORING AND RECALLING The scale can store up to 10 sets of high and low limits in memory along with

Page 10 - 6.0 SYMBOLS AND INDICATORS

© Adam Equipment Company 2007 16 NOTE: 1. If the recalled limit is for parts counting, the display will show the last sample value used,

Page 11 - 9.0 AUTO POWER OFF

© Adam Equipment Company 2007 17 if 3500g is placed on the scale and percent weighing is selected, the display will show 100.00%. Rem

Page 12 - 10.0 OPERATIONS

© Adam Equipment Company 2007

Page 13

© Adam Equipment Company 2007 18 NOTE: 1. The accumulation function is available only during weighing. It is disabled during parts cou

Page 14

© Adam Equipment Company 2007 19 • To view the total in memory press the [Print] key when the scale is at zero. The display will show the total

Page 15

© Adam Equipment Company 2007 20 11.0 RS-232 INTERFACE The CBK Series are supplied with bi-directional RS-232 interface as standard

Page 16

© Adam Equipment Company 2007 21 Data Format-Parts Counting Output: Weight, Unit weight and number of parts are printed. Data Format- Memory Re

Page 17

© Adam Equipment Company 2007 22 NOTE: 1. The accumulated total will not be sent to the RS-232 when the continuous print is turned on.

Page 18

© Adam Equipment Company 2007 23 12.0 CALIBRATION • The CBK scales are calibrated using kilogram weights and CBKa scales are calibrated using

Page 19

© Adam Equipment Company 2007 24 13.0 PARAMETER SETTINGS Pressing the [Func] key allows the user to access the parameters for customi

Page 20

© Adam Equipment Company 2007 25 Parameter Description Options Default setting F1 PCt This parameter allows the user to enter the Percen

Page 21

© Adam Equipment Company 2007 26 13.2 RS-232 PARAMETERS • Shortcut to enter this group is to press and hold the [Print] key for 4 secon

Page 22 - 11.0 RS-232 INTERFACE

© Adam Equipment Company 2007 27 Scale will perform the following, depending on the Accumulation and Print Settings: ACCUMULATION SETTINGS PRINT

Page 23

© Adam Equipment Company 2007 1 CONTENTS 1.0 INTRODUCTION ...

Page 24

© Adam Equipment Company 2007 28 S2 bL Backlight set to always on, always off or automatic on whenever a weight is placed or a key is pressed EL

Page 25 - 12.0 CALIBRATION

© Adam Equipment Company 2007 29 14.0 ERROR MESSAGES During the initial power-on testing or during operation, the scale may show an error messa

Page 26 - 13.0 PARAMETER SETTINGS

© Adam Equipment Company 2007 30 15.0 REPLACEMENT PARTS AND ACCESSORIES If you need to order any spare parts and accessories, contact your suppli

Page 27

© Adam Equipment Company 2007 31 17.0 WARRANTY INFORMATION Adam Equipment offers Limited Warranty (Parts and Labour) for the components fa

Page 28

© Adam Equipment Company 2007 32 18.0 APPENDIX

Page 29 - PRINT SETTINGS

Manufacturer’s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards, following th

Page 30

ADAM EQUIPMENT is an ISO 9001:2000 certified global company with more than 35 years experience in the production and sale of electronic weighing eq

Page 31 - 14.0 ERROR MESSAGES

© Adam Equipment Company 2007 2 1.0 INTRODUCTION • The CBK range of scales provides an accurate, fast and versatile general purpose weighing

Page 32 - 16.0 SERVICE INFORMATION

© Adam Equipment Company 2007 3 2.0 SPECIFICATIONS CBK 4 CBK 8H CBK 8 CBK 16 CBK 32 CBK 48 Kilograms Maximum Capacity

Page 33 - 17.0 WARRANTY INFORMATION

© Adam Equipment Company 2007 4 OTHER SPECIFICATIONS Units of measure CBK Series- kg, g CBKa Series- kg, g, lb, oz, lb:oz Interface RS-232 b

Page 34 - 18.0 APPENDIX

© Adam Equipment Company 2007 5 3.2 LOCATING • The scales should not be placed in a location that will reduce the accuracy. • A

Page 35

© Adam Equipment Company 2007 6 3.2 SETTING UP • The CBK Series comes with a stainless steel platform packed separately. • Place t

Page 36 - @Adam Equipment Company 2007

© Adam Equipment Company 2007 7 4.0 KEYPAD KEYS PRIMARY FUNCTION SECONDARY FUNCTION [Zero] Sets the zero point for all subsequent

Comments to this Manuals